Configured Specifications

Type Building Block Number of Inputs/Outputs(Point) 4096
Program size(k step) 40 RS232
USB Ethernet
CC-Link CE
UL Endian Format (Memory Mapping)
Basic Command Processing Speed (LD Command)(μs) 0.00098 Maximum Number of Controlled Axes(Axis)

 

R04CPU Performance Specifications

Hardware Specification
Calculation Control Method Stored Program Repeating Operation
Input/Output Control Method Refresh Method
(Direct access input/output is possible by specifying the direct access input/output (DX, DY).)
Command Processing Time LD X0 0.98 ns
MOV D0 D1 1.96 ns
Command Processing Time (ST Language) IF Command 1.96 ns
CASE Command 1.96 ns
FOR Command 1.96 ns
Memory Capacity Program Capacity 40K steps (160 KB)
Program Memory 160 KB
SD Memory Card SD Memory Card Capacity
(SD/SDHD Memory Card: maximum 32 GB)
Device / Label Memory 400 KB
Signal Flow Memory Area For Program 5 KB
Area For FB 256 KB
Data Memory 2 MB
Function Memory 5,120 KB
CPU Buffer Memory 1,072 KB (536K words)
(including cyclic communication area [24K words])
Refresh Memory 2,048 KB
Maximum File Storage Capacity Program Memory Program file capacity: 124
FB file capacity: 64
Device / Label Memory (File Storage Area) 324
(regardless of use of expanded SRAM cassette)
Data Memory 256
Function Memory 512
SD Memory Card · NZ1MEM-2GBSD: 256
· NZ1MEM-4GBSD, NZ1MEM-8GBSD, NZ1MEM-16GBSD: 32,767
Maximum Folder Capacity Data Memory 256 pcs
Function Memory 512 pcs
SD Memory Card · NZ1MEM-2GBSD: 256
· NZ1MEM-4GBSD, NZ1MEM-8GBSD, NZ1MEM-16GBSD: 32,767
USB Port USB2.0 High Speed (miniB) × 1
Ethernet Port 10BASE-T/100BASE-TX × 1
Clock Function Year, month, day, hour, minutes, seconds, day of the week (automatic detection of leap year)
-1.00 to +1.00 s/d at 0 to 55°C
Power Interruption Hold Retention Method Capacitor
Retention Period 3 minutes
Data To Be Retained Device / Label Memory, Clock Data
Allowable Momentary Power Loss Duration According to the power supply unit.
5 V DC Internal Current Consumption 0.67 A
External Dimensions Height (H) 106 mm (98 mm at the base unit mounting part)
Width (W) 27.8 mm
Depth (D) 110 mm
Mass 0.20 kg
Programming Specification
Programming Language Ladder Diagram (LD), Sequential Function Chart (SFC), Structured Text (ST), Function Block Diagram (FBD/LD)
Programming Expansion Function Function Block (FB), Label Programming (System/Local/Global)
Program Operation Execution Type General Program Initial execution type, scan execution type, cyclic execution type, event execution type, standby type
Interrupt Type General Program Interruption by internal timer (I28 to I31), interruption by high-speed internal timer 1 (I49), interruption by high-speed internal timer 2 (I48), interruption from unit, inter-unit synchronous interruption (I44), inter-multi-CPU synchronous interruption (I45)
Program Execution Capacity General Program 124
FB File Capacity FB File 64
Takt Performance Constant Scan 0.2 to 2,000 ms (can be set in 0.1 ms intervals)
Periodic Interrupt Interruption By Internal Timer (I28 To I31) 0.5 to 1,000 ms (can be set in 0.5 ms intervals)
Interruption By High-Speed Internal Timer 1 (I49) 0.05 to 1,000 ms (can be set in 0.05 ms intervals)
Interruption By High-Speed Internal Timer 2 (I48) 0.05 to 1,000 ms (can be set in 0.05 ms intervals)
Inter-Unit Synchronous Interruption (I44) 0.1 to 10.00 ms (can be set in 0.05 ms intervals)
Inter-Multi-CPU Synchronous Interruption (I45) 0.1 to 10.00 ms (can be set in 0.05 ms intervals)
Timer Function Low-Speed Timer 1 to 1,000 ms (default 100 ms)
High-Speed Timer 0.01 to 100 ms (default 10 ms)
Long Timer 0.001 to 1,000 ms (default 0.001 ms)
Number Of Inputs/Outputs 4,096 points
Number Of User Devices Input [X] 12,288 points (fixed)
Output [Y] 12,288 points (fixed)
Internal Relay [M] 12,288 points (can be changed with parameter)
Latch Relay [L] 8,192 points (can be changed with parameter)
Link Relay [B] 8,192 points (can be changed with parameter)
Link Special Relay [SB] 2,048 points (can be changed with parameter)
Annunciator [F] 2,048 points (can be changed with parameter)
Edge Relay [V] 2,048 points (can be changed with parameter)
Step Relay [S] 0 points (can be changed with parameter)
Timer System Timer [T] 1,024 points (can be changed with parameter)
Long Timer [LT] 1,024 points (can be changed with parameter)
Integration Timer System Integration Timer [ST] 0 points (can be changed using parameters)
Long Integration Timer [LST] 0 points (can be changed using parameters)
Counter System Counter [C] 512 points (can be changed with parameter)
Long Counter [LC] 512 points (can be changed using parameters)
Data Register [D] 18,432 points (can be changed with parameter)
Link Register [W] 8,192 points (can be changed with parameter)
Link Special Register [SW] 2,048 points (can be changed with parameter)
Number Of System Devices Special Relay [SM] 4,096 points (fixed)
Special Register [SD] 4,096 points (fixed)
Function Input [FX] 16 points (fixed)
Function Output [FY] 16 points (fixed)
Function Register [FD] 5 points × 4 words (fixed)
Number Of File Registers File Register [R/ZR] 0 points (can be changed using parameters)
Number Of Index Registers Index Register [Z] 20 points (can be changed with parameter up to 24 points)
Long Index Register [LZ] 2 points (can be changed with parameter up to 12 points)
Number Of Pointers Pointer [P] (Global/Local) 8,192 points (can be changed with parameter up to 16,384 points)
Interruption Pointer [I] 1,024 points (fixed)
Number Of Link Direct Devices Link Input [J□X□] Up to 16,384 points
Link Output [J□Y□] Up to 16,384 points
Link Relay [J□B□] Up to 32,768 points
Link Register [J□W□] Up to 131,072 points
Link Special Relay [J□SB□] Up to 512 points
Link Special Register [J□SW□] Max. 512 points
Number Of Unit Access Devices Intelligent Function Unit Device [U□G□] Up to 268,435,456 points
Number Of CPU Buffer Memory Access Devices Buffer Memory [U3E□G□] Max. 268,435,456 points
Cyclic Communication Area Of Buffer Memory [U3E□HG□] Up to 12,288 points
Number Of Refresh Data Registers Refresh Data Register [RD] 524,288 points (up to 1,048,576 points)
Number Of Nestings Nesting [N] 15 points
Number Of Other Devices SFC Block Device [BL] 320 points
SFC Transfer Device [TR] 0 points (can be used as device comment only)
Built-In Ethernet Function Part
Transmission Specification Data Transmission Speed 100 / 10 Mbps
Communication Mode 100BASE-TX: full duplex / half duplex
10BASE-T: full duplex / half duplex
Interface RJ45 (AUTO MDI / MDI-X)
Transmission Method Base Band
Maximum Frame Size 1,518 bytes
Jumbo Frame Not available
Maximum Segment Length 100 m (Length between the hub and the node)
IP Version IPv4-compatible
Sending/Receiving Data Storage Memory Number Of Simultaneous Available Openings 16 connections (connections can be used in the program)
Socket Communication 5K words × 16

R04CPU General Specifications

Ambient Operating Temperature 0 to 55°C (Base unit for high-temperature is not used.)
0 to 60°C (Base unit for high-temperature is used.)
Ambient Storage Temperature -25 to 75℃
Ambient Operating Humidity 5 to 95% RH, assuming no condensation
Ambient Storage Humidity 5 to 95% RH, assuming no condensation
Vibration Resistance JIS B 3502, IEC 61131-2 compliant Under Intermittent Vibration Frequency: 5 to 8.4 Hz, Single amplitude: 3.5 mm
Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m/s2
Sweeps: 10 sweeps in each direction of in X, Y and Z
Under Continuous Vibration Frequency: 5 to 8.4 Hz, Single amplitude: 1.75 mm
Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m/s2
Impact Resistance JIS B 3502, IEC 61131-2 compliant
(147 m/s2, 3 times in each direction of X, Y and Z)
Operating Atmosphere There shall be no corrosion gas or flammable gas and not much conductive dust.
Operating Altitude 0 to 2,000 m
Installation Location Inside the control panel
Overvoltage Category II or lower
Pollution Degree 2 or less
Equipment Class Class I